From: Assessment of factors affecting fire performance of mattresses: a review
 | Ticking | Type of Solid core | PHRR at 50 kW/m2 | FIGRA | Smoke parameter |
---|---|---|---|---|---|
M01 | Polyvinlychloride | PUF /TDI | 1630 | 28 | 2.60 |
M04 | Polyvinlychloride with cotton backing | Latex (butadiene-styrene) | 1190 | 25 | 9.38 |
M05 | Rayon fabric | PUF | 960 | 27 | 0.33 |
M08 | Cotton fabric | Polychloroprene | 525 | 131 | 0.56 |
M09 | Polyvinlychloride with nylon fabric reinforcement | Polyurethane /TDI | 1050 | 27 | 1.19 |
M10 | Polyvinlychloride with nylon fabric reinforcement | Polychloroprene | 470 | 52 | 0.89 |
M11 | Cotton fabric | Polychloroprene | 386 | 129 | 0.23 |
M12 | Cotton fabric | Polychloroprene | 334 | 28 | 0.40 |
M13 | Cotton fabric | Polychloroprene | 519 | 216 | 0.76 |
M14 | Polyvinlychloride | Polyvinlychloride | 585 | 4 | 1.93 |
M15 | Polyvinlychloride with nylon fabric reinforcement | Hydrophilic PUF | 198 | 40 | Â |
M16 | Cotton fabric | PUF | 658 | 7 | 1.31 |
M18 | Cotton fabric | PUF | 728 | 73 | 0.05 |
M20 | Polyvinlychloride | PUF | 950 | 26 | 1.97 |
M22 | Polyvinlychloride with nylon fabric reinforcement | Hydrophilic PUF | 224 | 8 | 0.70 |
M23 | Polyvinlychloride | PVC Nitrile | 554 | 35 | 4.46 |
M24 | Fiberglass coated with polyvinlychloride | PVC Nitrile | 313 | 12 | 0.82 |
M25 | Polyvinlychloride with nylon fabric reinforcement | Hydrophilic PUF | 168 | 6 | 0.20 |